Carpentry Free · No signup

Stair Stringer Calculator

Turn any floor-to-floor rise into equal risers, a cut-ready stringer length and an IRC R311.7 pass/fail — with a live side-elevation blueprint.

Formula-verified · IRC R311.7.5 · IRC R311.7.1 · Runs entirely in your browser. Nothing is uploaded.

Stair inputs

IRC R311.7
in9' · 108"
9' · 108"
in
in
in
in OC
Top step mount
Dropped: separate top tread one riser below the landing.
Stringer board
Tread thickness
Risers
15risers
14 treads to cut
Exact unit rise
7-3/16"
7.2" · 183 mm
Total run
12' 3"
147" · 14 × 10.5"
Stringer boards
20 fteach
4 × 2x12 @ 12" OC
IRC R311.7 compliant15 risers at 7-3/16" · 14 treads at 10.5" · 5.312" throat
R311.7

Live blueprint

Side elevation
SIDE ELEVATION · STRINGER PROFILE2x12 · 11-1/4" actual · 4 stringers @ 12" OCTOP FLOOR5-5/16" THROATPROPORTIONAL SIDE VIEW · NOT A CUT LISTNOSING NOT INCLUDED · VERIFY FIELD MEASUREMENTS
Ghost outline = 2x12 stringerAmber = notch triangles
  • Riser height: 7-3/16" exact unit rise (max 7-3/4") IRC R311.7.5.1
  • Tread depth: 10-1/2" unit run (min 10") IRC R311.7.5.2
  • Stairway width: 36" clear width (min 36") IRC R311.7.1
  • Remaining throat depth: 5-5/16" throat on a 2x12 (3-1/2" min, 5" recommended) Stringer structure
  • Riser uniformity: All risers equal by design — 0" variance (max 3/8") IRC R311.7.5.1

Cut list & material takeoff

Live
Quantities recalculate with every input change · Dropped top step (standard)
QtyItemCut / size
42x12 stringers20 ft · 11-1/4" wide
14Treads10-1/2" deep × 36" wide
15Risers (equal)7-3/16" finished height
8Stringer hangers / bracketsSimpson LSC or equal
1Handrail (4+ risers)12' 3" run + 15 risers
  • 4 stringers at 12" OC keeps every tread span under 16".
  • Tread depth includes any nosing. Keep the finished nosing projection between 3/4 in and 1-1/4 in.
  • A graspable handrail is required on at least one side for stairs with four or more risers (IRC R311.7.8).
Pre-calculated

Standard stair stringer rise / run chart

2×12 · 10-1/2" tread · 7-1/4" target
Rises from 24 in to 108 in · 36 in stair width · 16 in stringer spacing · 12 in cut allowance included
Total rise Risers Exact unit rise Treads Total run Min. 2×12 Throat
2' 4 6" 3 2' 7-1/2" 8 ft 6-1/16"
2' 6" 5 6" 4 3' 6" 8 ft 6-1/16"
3' 5 7-3/16" 4 3' 6" 8 ft 5-5/16"
3' 6" 6 7" 5 4' 4-1/2" 8 ft 5-7/16"
4' 7 6-7/8" 6 5' 3" 8 ft 5-1/2"
4' 6" 8 6-3/4" 7 6' 1-1/2" 10 ft 5-9/16"
5' 9 6-11/16" 8 7' 10 ft 5-5/8"
5' 6" 10 6-5/8" 9 7' 10-1/2" 12 ft 5-11/16"
6' 10 7-3/16" 9 7' 10-1/2" 12 ft 5-5/16"
6' 6" 11 7-1/16" 10 8' 9" 12 ft 5-3/8"
7' 12 7" 11 9' 7-1/2" 14 ft 5-7/16"
7' 6" 13 6-15/16" 12 10' 6" 14 ft 5-1/2"
8' 14 6-7/8" 13 11' 4-1/2" 16 ft 5-1/2"
8' 6" 15 6-13/16" 14 12' 3" 16 ft 5-9/16"
9' 15 7-3/16" 14 12' 3" 20 ft 5-5/16"

Min. 2×12 is the shortest stocked board that covers the diagonal plus a 12 in cut allowance. Throat values below 3-1/2 in fail the structural check; 3-1/2 in to 5 in is a caution zone.

Show your math

Exact stair stringer formulas

1. Equal risers and treads

risers   = ceil(total rise ÷ target unit rise)
unit rise = total rise ÷ risers
treads    = risers − 1
total run = treads × unit run

Always round the riser count up. That guarantees the finished unit rise is at or below your target instead of above it.

2. Stringer diagonal and board length

diagonal          = √(total rise² + total run²)
required board    = diagonal + 12 in cut allowance
stock board       = next 8, 10, 12, 14, 16 or 20 ft length

The 12 inches cover plumb cuts and layout trimming at both ends. Lay out the notches on the board before cutting the ends square.

3. Remaining throat depth

throat = board width − (unit rise × unit run) ÷ √(unit rise² + unit run²)

The second term is the perpendicular depth of the notch triangle. Subtract it from the dressed board width (11-1/4 in for a 2×12, 9-1/4 in for a 2×10) to get the wood left under the notch.

4. Stringer count

stringers = ceil(stair width ÷ max stringer spacing) + 1
actual OC = stair width ÷ (stringers − 1)

One stringer at each rim plus enough interior stringers that no tread span exceeds the requested maximum. A 36 in stair at 16 in OC resolves to four stringers at 12 in OC.

Worked US example — 9 ft floor-to-floor rise

Rise: 108 in. Target: 7-1/4 in. Tread: 10-1/2 in.

Risers = ceil(108 ÷ 7.25) = ceil(14.90) = 15. Unit rise = 108 ÷ 15 = 7.2" (7-3/16"). Treads = 15 − 1 = 14. Total run = 14 × 10.5 = 147 in (12'-3").

Diagonal = √(108² + 147²) = 182.41 in. Required board = 182.41 + 12 = 194.41 in, so use a 20 ft 2×12.

Throat = 11.25 − (7.2 × 10.5) ÷ 12.732 = 11.25 − 5.94 = 5.31" (5-5/16"), which passes the 3-1/2 in minimum and clears the 5 in target.

At 36 in wide and 16 in OC, stringers = ceil(36 ÷ 16) + 1 = 4 at 12 in OC. IRC check: PASS.

US homeowner questions

Stair stringer FAQs

How many risers does a 9-foot stair rise need?

A 108-inch rise needs 15 risers at 7.2 inches each (7-3/16 inches), which produces 14 treads. Dividing 108 by the 7-1/4 inch target gives 14.9, so you round up to 15 risers and let each riser come out slightly shorter. Every riser must stay at or under 7-3/4 inches under IRC R311.7.5.1.

What is the minimum throat depth for a stair stringer?

Most framers treat 3-1/2 inches as the absolute minimum remaining throat and 5 inches as the practical target. The throat is the wood left between the inside corner of a tread notch and the bottom edge of the stringer, measured perpendicular to the board. A 2x12 at a 7-1/4 inch rise and 10-1/2 inch run leaves about 5-5/16 inches; a 2x10 leaves about 3-5/16 inches and is marginal.

Can I use a 2x10 instead of a 2x12 for stair stringers?

Sometimes, but the throat check usually fails. A dressed 2x10 is 9-1/4 inches wide versus 11-1/4 inches for a 2x12. With a 7-1/4 inch rise and 10-1/2 inch run the 2x10 leaves only about 3-5/16 inches of throat, below the 3-1/2 inch minimum. Shorter risers or deeper treads can make a 2x10 work; this calculator flags the result per stringer size.

How long of a board do I need for stair stringers?

Take the diagonal of total rise and total run, then add a 12-inch cutting allowance and round up to a stocked length. A 9-foot rise with a 12-foot-3-inch run measures about 182-7/16 inches on the diagonal, so the calculator calls for a 20-foot 2x12. Always lay out the notches on the actual board before trimming the ends.

What is the difference between a dropped and a flush top step?

A dropped top step sets a separate tread one riser below the upper landing, so the finished floor becomes the top riser. A flush top step attaches the stringer directly below the landing framing and uses the floor surface as the top step. The riser and tread counts are the same; the difference is how the stringer is notched and attached at the top.

Powered by YardToRoof.com — free US carpentry calculators Open the full Stair Stringer Calculator ↗