Stair Stringer Calculator
Turn any floor-to-floor rise into equal risers, a cut-ready stringer length and an IRC R311.7 pass/fail — with a live side-elevation blueprint.
Stair inputs
Live blueprint
- Riser height: 7-3/16" exact unit rise (max 7-3/4") IRC R311.7.5.1
- Tread depth: 10-1/2" unit run (min 10") IRC R311.7.5.2
- Stairway width: 36" clear width (min 36") IRC R311.7.1
- Remaining throat depth: 5-5/16" throat on a 2x12 (3-1/2" min, 5" recommended) Stringer structure
- Riser uniformity: All risers equal by design — 0" variance (max 3/8") IRC R311.7.5.1
Cut list & material takeoff
Live| Qty | Item | Cut / size |
|---|---|---|
| 4 | 2x12 stringers | 20 ft · 11-1/4" wide |
| 14 | Treads | 10-1/2" deep × 36" wide |
| 15 | Risers (equal) | 7-3/16" finished height |
| 8 | Stringer hangers / brackets | Simpson LSC or equal |
| 1 | Handrail (4+ risers) | 12' 3" run + 15 risers |
- 4 stringers at 12" OC keeps every tread span under 16".
- Tread depth includes any nosing. Keep the finished nosing projection between 3/4 in and 1-1/4 in.
- A graspable handrail is required on at least one side for stairs with four or more risers (IRC R311.7.8).
Job spec
- Total rise 108" (9')
- Risers 15 @ 7-3/16"
- Treads 14 @ 10.5"
- Total run 147" (12' 3")
- Stringer 4 × 2x12 × 20 ft
- Throat depth 5.312" (pass)
- IRC R311.7 PASS
- Top mount Dropped top step (standard)
Store shopping list
- 4 — 2x12 × 20 ft pressure-treated stringer boards
- 14 — Treads, min 10-1/2" deep × 36" wide
- 1 — Tube construction adhesive + 3" structural screws for treads and stringer hangers
- 1 — tube construction adhesive
- 1 — 4 ft level and framing square
Standard stair stringer rise / run chart
| Total rise | Risers | Exact unit rise | Treads | Total run | Min. 2×12 | Throat |
|---|---|---|---|---|---|---|
| 2' | 4 | 6" | 3 | 2' 7-1/2" | 8 ft | 6-1/16" |
| 2' 6" | 5 | 6" | 4 | 3' 6" | 8 ft | 6-1/16" |
| 3' | 5 | 7-3/16" | 4 | 3' 6" | 8 ft | 5-5/16" |
| 3' 6" | 6 | 7" | 5 | 4' 4-1/2" | 8 ft | 5-7/16" |
| 4' | 7 | 6-7/8" | 6 | 5' 3" | 8 ft | 5-1/2" |
| 4' 6" | 8 | 6-3/4" | 7 | 6' 1-1/2" | 10 ft | 5-9/16" |
| 5' | 9 | 6-11/16" | 8 | 7' | 10 ft | 5-5/8" |
| 5' 6" | 10 | 6-5/8" | 9 | 7' 10-1/2" | 12 ft | 5-11/16" |
| 6' | 10 | 7-3/16" | 9 | 7' 10-1/2" | 12 ft | 5-5/16" |
| 6' 6" | 11 | 7-1/16" | 10 | 8' 9" | 12 ft | 5-3/8" |
| 7' | 12 | 7" | 11 | 9' 7-1/2" | 14 ft | 5-7/16" |
| 7' 6" | 13 | 6-15/16" | 12 | 10' 6" | 14 ft | 5-1/2" |
| 8' | 14 | 6-7/8" | 13 | 11' 4-1/2" | 16 ft | 5-1/2" |
| 8' 6" | 15 | 6-13/16" | 14 | 12' 3" | 16 ft | 5-9/16" |
| 9' | 15 | 7-3/16" | 14 | 12' 3" | 20 ft | 5-5/16" |
Min. 2×12 is the shortest stocked board that covers the diagonal plus a 12 in cut allowance. Throat values below 3-1/2 in fail the structural check; 3-1/2 in to 5 in is a caution zone.
Exact stair stringer formulas
1. Equal risers and treads
risers = ceil(total rise ÷ target unit rise) unit rise = total rise ÷ risers treads = risers − 1 total run = treads × unit run
Always round the riser count up. That guarantees the finished unit rise is at or below your target instead of above it.
2. Stringer diagonal and board length
diagonal = √(total rise² + total run²) required board = diagonal + 12 in cut allowance stock board = next 8, 10, 12, 14, 16 or 20 ft length
The 12 inches cover plumb cuts and layout trimming at both ends. Lay out the notches on the board before cutting the ends square.
3. Remaining throat depth
throat = board width − (unit rise × unit run) ÷ √(unit rise² + unit run²)
The second term is the perpendicular depth of the notch triangle. Subtract it from the dressed board width (11-1/4 in for a 2×12, 9-1/4 in for a 2×10) to get the wood left under the notch.
4. Stringer count
stringers = ceil(stair width ÷ max stringer spacing) + 1 actual OC = stair width ÷ (stringers − 1)
One stringer at each rim plus enough interior stringers that no tread span exceeds the requested maximum. A 36 in stair at 16 in OC resolves to four stringers at 12 in OC.
Worked US example — 9 ft floor-to-floor rise
Rise: 108 in. Target: 7-1/4 in. Tread: 10-1/2 in.
Risers = ceil(108 ÷ 7.25) = ceil(14.90) = 15. Unit rise = 108 ÷ 15 = 7.2" (7-3/16"). Treads = 15 − 1 = 14. Total run = 14 × 10.5 = 147 in (12'-3").
Diagonal = √(108² + 147²) = 182.41 in. Required board = 182.41 + 12 = 194.41 in, so use a 20 ft 2×12.
Throat = 11.25 − (7.2 × 10.5) ÷ 12.732 = 11.25 − 5.94 = 5.31" (5-5/16"), which passes the 3-1/2 in minimum and clears the 5 in target.
At 36 in wide and 16 in OC, stringers = ceil(36 ÷ 16) + 1 = 4 at 12 in OC. IRC check: PASS.
Stair stringer FAQs
How many risers does a 9-foot stair rise need?
A 108-inch rise needs 15 risers at 7.2 inches each (7-3/16 inches), which produces 14 treads. Dividing 108 by the 7-1/4 inch target gives 14.9, so you round up to 15 risers and let each riser come out slightly shorter. Every riser must stay at or under 7-3/4 inches under IRC R311.7.5.1.
What is the minimum throat depth for a stair stringer?
Most framers treat 3-1/2 inches as the absolute minimum remaining throat and 5 inches as the practical target. The throat is the wood left between the inside corner of a tread notch and the bottom edge of the stringer, measured perpendicular to the board. A 2x12 at a 7-1/4 inch rise and 10-1/2 inch run leaves about 5-5/16 inches; a 2x10 leaves about 3-5/16 inches and is marginal.
Can I use a 2x10 instead of a 2x12 for stair stringers?
Sometimes, but the throat check usually fails. A dressed 2x10 is 9-1/4 inches wide versus 11-1/4 inches for a 2x12. With a 7-1/4 inch rise and 10-1/2 inch run the 2x10 leaves only about 3-5/16 inches of throat, below the 3-1/2 inch minimum. Shorter risers or deeper treads can make a 2x10 work; this calculator flags the result per stringer size.
How long of a board do I need for stair stringers?
Take the diagonal of total rise and total run, then add a 12-inch cutting allowance and round up to a stocked length. A 9-foot rise with a 12-foot-3-inch run measures about 182-7/16 inches on the diagonal, so the calculator calls for a 20-foot 2x12. Always lay out the notches on the actual board before trimming the ends.
What is the difference between a dropped and a flush top step?
A dropped top step sets a separate tread one riser below the upper landing, so the finished floor becomes the top riser. A flush top step attaches the stringer directly below the landing framing and uses the floor surface as the top step. The riser and tread counts are the same; the difference is how the stringer is notched and attached at the top.